AirVision Version 2.0 Release NotesIssues Found and Resolved
- Repaired Modbus digital I/O download
- Fixed configuration issues with Logger Average Alarm form (not allowing more than one program with the same interval, not requiring ignore flag, improving list of flags allowed for triggers/filters)
- Resolved download issues with General Channel
- Fixed incorrect label on WSP Channel configuration form.
- Fixed appearance of zeroes for invalidated data on Monthly Report for wind channels
- Fixed some ADVP triggering conditions, “Object Reference” errors introduced in 1.0.5.
- Fixed issue with minute data ADVP and flag over-write on next poll.
- Fixed issue with assigning new users to existing groups.
- Fixed default time range in Manual ADVP Utility
- Fixed issue with deleted users showing up in Groups Editor
- Hid “AirVision” user to prevent accidental deletion.
- Fixed limitations with naming Scheduled Report files and extensions
Enhancements
- Calibration Graph Query allows filtering by Cal Program Name
- Put “Warm Start” option back into Logger Download
- Added Single Channel Download option in Logger Download
- Cal config form now allows math constant as expected value
- Allow historical comparison of N days, weeks, in single-parameter graph
- Added graph of raw vs. validated data in single parameter graph
- Removed limitation of maximum # of parameters in graph
- Added Audit Trail Report for modified data
- Added Annotations ReportRemoved logger calibration flags from Calibration Data Editor
- Added Totalize In Reports option in Parameter Editor
- Added record type selectors in AQS text report.
- Manual Poll now updates Last Poll Time in task Status
- Added optional module for Real-Time Trending / AV-Trend Product
- Allow logger channel to map to another site, if needed (to support pseudo-sites for AIRNow).
- Allow generation of 5-minute SO2 records for AQS.
- Add "Parameter Report Order" to Parameter Editor to control order of printing in Daily Report and Monthly Report
- Added Help and Web Link menu items / menu group
- Made password hashing FIPS compliant
- Added capability for Logger Messages to automatically go into Site Logbook when polled.
- Added “Set Method Code“ function to Data Editor and Batch Data editor
- Added ability to set value of null value records in Batch Edit
AirVision Version 1.0.5 Maintenance Release Notes
Issues Found and Resolved
- Fixed scroll to bottom when saving in Flags Editor
- Fixed Affected Channel save issue in Cal Editor
- Fixed odd behavior when editing 001d interval data in Average Data Editor
- Fix to output lines form in User Initiated calibration configuration editor.
Enhancements
- Logbook report can now query by site
- Alberta reporting completed
- Type “E” calibration support added
- Flags now shown in hover-over on graph / scatter plot in Data Editor
- More efficient management of modem hangup process
- Added “whitespace” delimiter to File Import Tool
- Added download of Scan Interval to Modbus channels
- File Import Tool will now skip non-numeric data, rather than stopping.
- Direct polling of API analyzers available (requires license).
AirVision Version 1.0.4 Maintenance Release Notes
Issues Found and Resolved
- Fixed Modbus registers for API instruments.
Enhancements
- Improved polling speed through larger batching
AirVision Version 1.0.3 Maintenance Release Notes
Issues Found and Resolved
- Issue with AirNow Mnemonics caused AIRNow files to be not generated.
- Fixed “only positive time zone” requirement for OBS files
- Increased precision digits allowed in analog input configuration form.
- Fixed math channel download
- Fixed GSI driver for BAM1020
- Fixed some API GSI driver entries.
- Removed ability for user names to be changed, which mixed up auto-login password.
- Fixed quirk in user editor where a newly created user looks like it disappears when you click on another user.
- Made retry selections in task scheduler less prevalent, since users should utilize modem / logger retry settings primarily.
- Fixed quirk with editing email account of user that causes field to blank (although it is saved).
- Fixed quirk with checkbox in AirNow transfer program editor.
- Restored logic to do zero crossover calculations on Daily Summary and Monthly report for WDR-like parameters
Enhancements
- Communication routes form moved from Server Configuration to Data Source Details – Logger configuration form. A new button is added to create a new route, if needed.
- Improved logger download to allow download of everything without cold start
- Allow download of more than one logger at a time.
- Editor now shows cells with more than one flag as pattern
- Improved error checking of user input fields and better error handling.
- Improved handling of polling and link to logger handoff with slow IP modems
- Support for non-US date formats
- File import will now ignore and go on when a parameter template is not found for a site, rather than stopping.
- Improved PM calculation editor, which is now part of the Sample Data Editor.
- Update NO2 AQI for new NAAQS
- Added GSI drivers for Vaisala WX520 and various Ecotech monitors
- Added File Import Template for Magee MicroAeth.
- Added form for user to update their own password
- Added item in AirVision options to print / capture application screen to file.
AirVision Version 1.0.2 Maintenance Release NotesIssues Found and Resolved
- Rare issue with some PCs not having Microsoft C Runtime DLL causing problems with link to logger resolved.
- Issue with “backspace” causing Link to Logger to disconnect resolved.
- Cleaned up a number of pick list forms with additional non-essential fields (ADVP, File Import Tool, etc)
- Fixed Site Metadata entry form
- Fixed round/truncate selector in Parameter Template (from text field to button selection)
- Fixed problem with display of relative time selection (last week, month, etc) for Vista / Windows 7 systems with certain Themes.
- Fixed quirks with behavior of Logbook Entry form.
- Fixed filtering of digital I/O Modbus in Data Source Details->Logger->Digital I/O.
- Fixed missing digital lines selector in Calibration Configuration editor.
- Fixed missing digital lines selector in Math Constants editor (for secondary / tertiary values)
- Fixed some issues with API GSI commands
- Fixed issue with Favorites in data editor bringing up additional parameter
- Fixed configuration forms for Linear Sigma and GSI-Met channel types.
Enhancements
- Added “remove invalid data” option to scatter plot
- Enhanced editor to show pattern if > 1 flag exists
- Now sorts loggers in Server Configuration alphabetically.
- Added API 300E and 700E Analyzers to Library
- Added Method Code to Linear Editor.
AirVision Version 1.0.1 Maintenance Release NotesIssues Found and Resolved
- Issues with being unable to see certain fields and buttons on lower-resolution screens have been resolved with the addition of new scroll bars.
- Issue with minimizing and re-maximizing the criteria area in certain reports and editors (resulting in some part of the criteria being hidden) have been resolved.
- Issue with creating a scheduled task report not defaulting to 001h interval and not being obvious that a report data interval has not been selected has been resolved.
- Various improvements in Link To Logger over TCP connections, solving the sometimes-hidden “are you sure” messages.
- Issue with Cross-Tab mode of Data Editor not always showing the last hour has been resolved
- Issue with data editor taking excessively long to retrieve data when the dynamic range of the data is very large (e.g., 0 – 100,000) has been resolved.
- Issue with setting identical TCP poll and telnet ports (e.g., Model 8816 on IP connections) has been resolved
- Windows 7 installation issues have been resolved.
- Typos in the Parameter Template descriptions related to NO, NO2 have been resolved.
- BAM polling / file import added provision to subtract 1 hour, because of the way BAMs time-tag their data.
- Performance improvements have been made for every large databases through additional indexing.
- Resolved some issues with storing parameter lists for scheduled reports.
- Speed up GSI acquisition intervals (set low in Version 1.0)
- Add iSeries analyzer tables for Modbus
- Added date range info to header of Statistical Report
- Improved analog setting labels in met channels
- Reorganized calibration report to print cals by day
- Resolved issues with “>” from imported data not showing in editor
- Added some missing trigger flags to pick list in Logger dial-out alarms.
- Resolved extra delimiter at end of AQS text report
- Resolved issue with entering negative number in zero in PARS forms
- Restored missing “Enabled” checkbox for digital event programs
- Fixed incomplete ‘restore from raw’ logic
New Functions
- Sample Data Editor has been improved.
- Calibration Data Editor has been added
- Precision and Accuracy tests have been added for customers with the PARS module opion
- Added ability to have scheduled reports saved to a disk file
- Added web service to allow query of AQI information (to replace E-DAS Access database function)
- Added Sample Data Report
- Updated E-DAS Data Import Utility to import sample data
- Added Modbus server.cfg file download capability for Modbus channels.
- Added utility to create parameter/average interval combinations in the database for File Import tool and manual data entry.
- Added utility for one-button export of configuration
Outstanding Known Issues:
- When setting e-mail address on user, the user must TAB off the email field before saving.